Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Audiometer KAU-A100 is a high-precision two channel diagnostic practical screening instrument to examine hearing acuity. Digital signal processing enables high quality masking and refractivity. Alphanumeric trans-reflective LCD screen displays sound output intensity, frequency and test information for visible results.
Specifications :
Type
Two-channel for independent outputs
Test Signal
Pure tone, Pulse tone, Warble tone, Narrowband noise
Output
TDH 39 Air conduction headset(L/R), B71 Bone conduction headset(L/R), Free Sound field
EN 60601-1, level 1 class B EN 60601-1-2 EN 60601-1-4 EN60645-1 EN60645-2 EN60645-4 ANSI S3.6-1996
Distortion
Air conduction: < 2.5% ; Bone conduction: < 5%
Warm-up Time
Less than 10 minutes
Connectivity
USB 2.0 data interface
Report format size
A4 or B5 format report
Calibration
Calibrates multiple types of earphone at the same time
Masking
Pure tone masking ; Ipsilateral masking
Power Supply
100V / 50 Hz to 240V / 60 Hz
Power Consumption
60 VA
Dimensions
450 x 300 x 110 mm
Weight
2.4 Kgs
Features :
Wide intensity range
AC up to 250 Hz – 8K Hz
BC up to 250 Hz – 6K Hz
Flexible for clinical and portable use
Special output (SF) [Optional]
Masking for both AC and BC
Built-in microphone for easy communication with subjects
Applications :
Used in ENT hospitals, research communities, rehabilitation centre and deaf training centres for clinical audiometry to test conductive hearing mechanisms.
Meditronics