Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Blood and Infusion Warmer KBIW-A200 is compact microprocessor-controlled in-line blood/infusion fluid warming system suitable for low to medium infusion featuring advanced thermal sensors, self-test facility and comprehensive malfunction alarms for optimized and safe inline bubble-free warming of blood and infusions therapy fluids. Dual loop tube position with dual-lock magnetic cover plate ensures uniform heat at slow fluid rate.
Specifications :
Temperature Range
37°C to 42°C
Temperature Accuracy
± 1.0°C
Warm-up Time
< 45 s (20°C to 36°C)
Power Consumption
80 VA
Warming Capacity
16 ml/min
Tube Diameter Range
3.5 mm ̶ 5.0 mm O.D.
Device Classification
Class I, Type B
Overheat Protection
43°C / 45°C / (48 ± 3)°C
Low Temperature Alarm
36 °C
Power Supply
230 V ± 10%, 50 ̶ 60 Hz
Dimensions
180 x 75 x 40 mm
Features :
Dry heat technology
In-line fluid warming
Dual-loop tube positioning
24 hours of continuous operation
Wide range of IV tube compatibility
Easy-to-mount clamp
Applications :
Used in operating rooms, surgical care wards, Intensive care unit, and other departments for warming blood components and enteral or parenteral nutrition fluids during massive transfusions, post-operative or critical-care nutrition to prevent hypothermia in patients.
Meditronics
Meditronics International House 82 Queens Road Brighton BN1 3XE; UK