Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Mammography system KBS-A101 is a breast imaging scanner with dedicated magnification system. Slim design and motorized movements enable easy breast positioning. Smooth compression platform with plate ensures uniform compression for increased breast tissue visibility.
Specifications :
Generator Type
High frequency inverter 40 kHz
Radiographic Ratings
Large focal point, 20-35 kV/10-510 mAs
Small focal point, 20-35 kV/ 10-110 mAs
Focal Size
Dual focus 0.5 mm
Input Power
Single phase AC 220 V, 50-60 Hz
Power Ratings
1.8 kW
Target Material
Molybdenum (Mo)
Port Material
Beryllium (Be)
Anode Heat Storage
35 KJ
Anode Cooling
Air cooling
Filtration
Molybdenum (0.03 mm) Al (O.5 mm)
C-arm vertical segment
580 mm
Rotational movement
+175⁰~-180⁰
SID
650 mm
Cassette image receptor
190 X 240 mm
Line Voltage
AC 220 V @ 15 A, Single phase
Dimensions
2050 x 600 x 1100 mm
Weight
240 kgs
Features :
High frequency focused Molybdenum target
Streamlined compression plate
High resolution imaging
Optimal dosage
Touch panel operation
Applications :
Used in radiology departments for enhanced visualization of breast tissue for mammary benign lumps, nodes, calcified points and early detection of malignant tumours.