Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Mobile X-ray machine KMX-A100 is an advanced x-ray imaging modality designed for easy mobility and handling during intra-hospital transport. Regulated voltage control ensures powerful and brief exposure yet stabilized x-ray output consistently. Focused and precise x-ray exposure with adjustable collimators reduces scatter enhancing image quality and contrast. Tube head cantilever allows easy source orientation suitable for different patient positions.
Specifications :
Focal Distance
430 × 430 mm
Source Head Range
550 mm - 1820 mm
Exposure Time
0.08 s - 6.32 s
Tube Focus
2.6 x 2.6 mm
Collimator Film (max)
1000 mm
Power Rating
5 kVA
Internal Resistance
≤1 Ω
Current
Max. 15 A
Power Supply
Voltage : 180 V - 240 V Frequency : 50Hz
Dimensions
1350 × 750 × 1500 mm
Weight
135 Kgs
Features :
Standard frequency X-ray generator
High imaging quality
Stabilized and short time exposure
Focused x-ray output
Easy and fast positioning
Simplistic operational console
Applications :
Used throughout the hospital from in-patient, to NICU, operating room, and emergency room as well as polyclinics to perform projection radiography readily on bedbound or critical patients for convenience.