Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Vital Sign Monitor KPM-A100 is a four parameter compact spot check device with graphic trends to illustrate patient status. Smooth crevice-free exterior with integrated handle aids portable usage reducing cross infection. Advanced software enables instant data download and tele-monitoring.
Specifications :
Vital Parameters
Type A
Type B
Type C
4 Parameters (NIBP,SpO2, PR, Temp)
3 Parameters (SpO2, PR, Temp)
3 Parameters (NIBP, SpO2, PR)
Display
240 x 320 dot matrix colour TFT
NIBP Measurement range
Adult: 30-255 mmHg Paediatric: 30-160 mmHg
NIBP Mode
Auto, Manual, STAT
NIBP Parameters
SYS, DIA, MAP
NIBP interval
Auto mode: 1, 2 , 3, 5, 10, 15, 20, 25, 30, 45, 60 mins STAT mode: 5 mins
Resolution
1 mmHg
NIBP Over-pressure protection
Adult: 300 mmHg Pediatric: 22 mmHg
SpO2 Measurement range
0 - 100%
SpO2 Accuracy
±2% (90-100)%, ±3% (70-89)%, <70% (unspecified)
SpO2 Resolution
0.01
PR Measurement range
30 bpm - 250 bpm
PR Accuracy
±1 bpm
PR Resolution
1bpm
Temp Probe
Body sensitive temperature sensor
Temp Measurement range
0⁰C to 50⁰C
Temp Accuracy
± 0.1⁰C
Temp Resolution
0.1⁰C
Graphic LCD size
44 x 59 mm
Audio-visual Alarms
Sensor-off alarm, Measurement out of user-defined limits
Data Transmission
USB-based transmission to PC Internet-based tele monitoring
Operational Temperature
0⁰C to 45⁰C
Relative Humidity
15% to 95%
Pressure
86 kPa – 106 kPa
Power Supply
Input power: AC 100-240V, 50-60Hz, 0.7A Output power: 5V,2.5A
Battery
2.8 A built-in rechargeable Li-ion battery Run Time : 5 hours Charging Time : 8 hours
Features :
2.8-inch screen display
Automatic shut-down and stand-by
Trend review up to 3888 groups
Audio-visual alarm system
Tele monitoring and USB connectivity
Battery status indicator
Applications :
Used in OPD, diagnostic centers, emergency wards, first-aid and rescue ambulatory care intended for spot checking, non-invasive monitoring or recording of vital body parameters.